From: Jim Meissner (jpmeissner_at_mindspring.com)
Date: 2002-02-04 17:05:54
Dear John:
About 10 years ago, I actually experimented using the idea that you present.
Although it makes sense from a theoretical standpoint, it is difficult to
implement in practice. The resultant "pin cushion" is very uncomfortable
as the pins tend to dig in. Maintaining the correct pressure is a
challenge. Each pin would have to have it's own spring load. Sleeping or
just putting your head on a pillow with this is not possible.
The conductive paste solves the problem. You might not consider this an
elegant solution, but it works.
ALSO, at this point in the project, why create more problems and challenges.
Go with what works.
It seems to me that with your skill, what you could contribute here is
software.
1-24-2002 message..... snip
> Writing the little interface code to transfer the data from the eeg to
the
> program is one of the simplest parts.
I keep hearing this! I have not seen any or even "simple" code. Where is
it?
end of snip......
Juergen P. (Jim) Meissner
Check out my Website at www.MeissnerResearch.com
Read about the benefits of the Brain State Synchronizer sounds for improving
your life and health.
----- Original Message -----
From: John Morrison <jmorrison_at_ahc.net.au>
To: <buildcheapeeg_at_yahoogroups.com>
Sent: Monday, February 04, 2002 10:11 AM
Subject: RE: [buildcheapeeg] Re: electrode idea
> Thanks
> So what I get from that is
> "Because of the irregular surface of the skin, such high capacitance can
> not be attained by just pressing metal electrodes on the skin. Therefore
we
> do not believe in the concept of a dry electrode for high quality
> bioelectric measurements, and as a result we do not offer such an
> electrode."
>
> But if the electrodes were pins (NOT sharp) then the irregular surface
> wouldn't be a problem and the GUNK factor would disappear. :-)
>
> ___________/-------
> |||||||||||
> SKIN
>
> Anyway We'll see
>
> John
>
> > -----Original Message-----
> > From: sleeper75se [mailto:sleeper75se_at_yahoo.se]
> > Sent: Monday, 4 February 2002 12:06 PM
> > To: buildcheapeeg_at_yahoogroups.com
> > Subject: [buildcheapeeg] Re: electrode idea
> >
> >
> > --- In buildcheapeeg_at_yahoogroups.com, "John Morrison" <jmorrison_at_ahc.net.au> wrote:
> > > OK Guys!!
> > >
> > > If this is just a stupid idea tell me!!!
> > >
> > > Is the goop or saline a necessary part of the circuit???
> >
> > Hi John,
> >
> > I don't really know, so you will have to try it when you get a
> > chance. Anyway, biosemi has something to say here:
> > http://www.biosemi.com/faq/without_paste.htm
> >
> > Regards,
> >
> > Andreas
> >
> >
> >
> > To unsubscribe from this group, send an email to:
> > buildcheapeeg-unsubscribe_at_egroups.com
> >
> >
> >
> > Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/
> >
> >
>
>
> To unsubscribe from this group, send an email to:
> buildcheapeeg-unsubscribe_at_egroups.com
>
>
>
> Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
>
>